Dil Seçimi

In insulation applications, it is necessary to determine the appropriate pipe insulation thickness.

The following table shows the optimum pipe insulation thicknesses. If the pipes are outdoors, insulation thickness of 10-20 mm shall be added.

Pipe Diameters

INSULATION THICKNESS THROUGH FLUID TEMPERATURE (mm)

DN

Inch

50°C

100 °C

150 °C

200 °C

250 °C

300 °C

350 °C

400 °C

450 °C

500 °C

550 °C

600 °C

650 °C

25

1

30

30

40

40

50

50

60

60

70

70

80

90

100

32

1 1/4

30

40

40

50

50

50

60

60

70

70

80

90

100

40

1 1/2

30

40

50

50

60

60

70

70

80

80

90

100

110

50

2

30

50

50

60

70

70

80

90

100

110

120

130

170

70

1 1/2

40

50

60

60

70

80

80

90

100

110

120

150

180

80

3   

40

60

60

70

70

80

80

90

110

120

140

160

180

100

4   

40

60

60

70

70

80

90

100

110

130

140

170

200

125

5   

50

60

60

70

80

90

100

110

120

130

150

170

220

150

6   

50

60

60

80

80

90

100

110

120

150

160

180

230

200

8   

60

70

70

90

100

110

120

120

140

160

180

220

270

250

10   

60

70

80

90

100

130

130

140

150

170

190

-

-

300

12   

60

80

80

100

110

130

140

140

160

180

200

-

-

350

14   

70

80

80

100

120

130

140

140

160

180

200

-

-

400

16   

70

80

80

110

120

130

140

150

160

180

200

-

-

450

18   

70

80

80

120

130

140

150

150

170

190

210

-

-

500

20   

70

80

80

120

130

170

150

160

170

190

220

-

-

Tank Surfaces

80

80

80

120

130

140

150

160

170

200

220

-

-

Ducts

60

80

80

90

100

120

120

130

140

160

200

-

-

(*Gökhan Özbek ’Heat Loss and Insulation in Pipes’ Excerpt from the article. A link to the article: www1.mmo.org.tr/resimler/dosya_ekler/122cb13c7a474c1_ek.pdf?dergi=158)

2019 CATALOG
We use cookies on our website to support technical features that enhance the user experience. For detailed information click here.